Warning – Enerpac PL200-Series User Manual
Page 9
9
PLB12
PLE5
PLE7
PLE9
PLE11
PLE14
Table 4 - PLB and PLE Series Extensions (optional accessories)
Extension
Model
Height (each)
Weight (each)
Extension
Model
Height (each)
Weight (each)
inches
mm
pounds
kg
inches
mm
pounds
kg
PLB12
12
305
44.2
20,0
PLE9
9
229
28.0
12,7
PLE5
5
127
24.6
11,2
PLE11
11
279
31.7
14,4
PLE7
7
178
29.9
13,6
PLE14
14
356
37.4
17,0
WARNING
Extensions PLE11, PLB12 or PLE14 are to be used with the “short” jack model PL20014-ASA only. Use of
these extensions on “tall” jack model PL20025-ASA will result in an excessive maximum lifting height. Load could become
unstable and drop, resulting in possible personal injury and/or property damage.
NOTICE: Dimensions and weights shown are approximate.
WARNING
Failure to observe the following precautions and instructions
may allow the load to shift or drop, resulting in possible
personal injury and/or property damage.
• Use only genuine Enerpac PLB, PLE and PLS Series
extensions and spacers with the Pow’R-LOCK
™ jack.
Never use extensions or spacers that are fabricated or that
are designed for use with another lifting device.
• Never exceed the maximum additional stack height for your
jack model. Refer to Table 6 for additional information. An
excessive stack height will reduce the stability of the jack.
PLS1
PLS2
Table 5 - PLS Series Spacers (optional accessories)
Spacer Model
Height (each)
Weight (each)
inches
mm
pounds
kg
PLS1
1.0
25
4.5
2,0
PLS2
2.0
51
9.1
4,1
NOTICE: Dimensions and weights shown are approximate.
WARNING
Failure to observe the following rules,
precautions, and conditions could result in an unstable lifting
arrangement. Load could shift or drop, resulting in possible
personal injury and/or property damage.
When using PLB, PLE or PLS Series extensions and spacers,
always obey the following rules, precautions, and conditions:
• Table 6 shows the maximum additional stack height (dimension
“X”) that is allowed. When installing extensions and spacers,
do not exceed this dimension for your jack model.
• The total height of the PLS Series spacers installed in the stack
must not exceed 2 inches [51 mm].
• Jack model PL20014-ASA: Only one PLB12 base extension
(if used) must be present in the stack, and the PLB12 must
always be located at the bottom of the stacking arrangement.
Do not attempt to stack two or more PLB12's together.
• Extensions PLE11, PLB12 and PLE14 are designed for use
with model PL20014-ASA only. To prevent unsafe operation,
do not use these extensions on jack model PL20025-ASA (see
warning statement at bottom of Table 4).
• Be especially careful to avoid off -center loads and side loads
when using extensions and spacers.
▲
▲
▲
▲
Use with jack model PL20014-ASA only.
▼
Use with jack model PL20014-ASA or PL20025-ASA.
▼
▼
▼