Caution, Notice – Enerpac PL200-Series User Manual
Page 2
2
2.0 PRODUCT DATA
Table 1 - General Specifi cations (notes and precautions)
Load Rating
(Maximum Capacity)
Model
US Tons
kN
WARNING
Do not exceed
jack load rating. Death, serious
personal injury and/or property
damage could result.
PL20014-ASA
200
1779
PL20025-ASA
200
1779
Weight
Model
Pounds
kg
Weight includes reservoir fi lled with
oil but does not include accessories,
such as cylinder adapter, extensions
or spacers.
PL20014-ASA
1105
501
PL20025-ASA
1320
599
Collapsed Height (fully retracted)
Model
inches
mm
Refer to tables 2 and 3,
item E1.
PL20014-ASA
34.0
864
PL20025-ASA
45.5
1156
Maximum Stroke (fully extended)
Model
inches
mm
Refer to tables 2 and 3,
item E2.
PL20014-ASA
14.0
356
PL20025-ASA
24.5
622
Hydraulic Pressure
Model
Max. Working Pressure at Load Rating
WARNING
The maximum
pressure of the jack hydraulic
system is factory set at 10000 psi
[700 bar]. Do not attempt to
readjust pressure relief valve.
Death, serious personal injury and/
or property damage could result.
psi
bar
PL20014-ASA
9898
682
PL20025-ASA
9898
682
Cylinder Advance Speed
Approximately 2.0 to 2.4 inches [51 - 61 mm] per minute.
NOTICE: Actual advance speed will vary depending on available air fl ow, pressure regulator setting,
pump speed, load weight, diameter of incoming air supply line and other variables.
Compressed Air
Requirements
Dynamic Air Pressure
Air Flow Volume
Typical
90 - 100 psi [6,2 - 6,9 bar]
130 - 150 CFM [3681 - 4247 l/min]
Minimum
50 - 60 psi [3,4 - 4,1 bar]
Maximum
120 psi [8,3 bar]
NOTICE: Specifi cations are subject to change without notice.
CAUTION
Failure to observe and comply with the following precautions
could result in minor or moderate personal injury. Property
damage could also occur.
• When jack is not in use, fully retract the cylinder and protect
the entire unit from external damage. Keep the jack clean,
avoid weld splatter, and store in a clean dry area. Failure
to observe these precautions may cause erratic operation,
reduced performance, increased wear and/or damage to
jack.
• Keep the jack away from fl ames and heat. For optimum
performance, do not expose the jack to temperatures
above 150 °F [65 °C]. Failure to observe these precautions
may cause erratic operation, reduced performance,
increased wear and/or damage to jack.
• Immediately replace worn or damaged parts with genuine
Enerpac parts. Enerpac parts are designed to fi t properly
and to withstand high loads. Non-Enerpac parts may break
or cause the jack to malfunction.
NOTICE
• The jack is not designed for long-term support of lifted objects.
If the load must remain supported for more than 30 days, use
appropriately rated load support devices to support the load.
• Hydraulic equipment must only be serviced by a qualifi ed
hydraulic technician. For repair service, contact the Enerpac
Authorized Service Center in your area.
1.3 Crush and Pinch Point Hazard
WARNING
CRUSH AND PINCH POINT HAZARD! Never
reach in between the cylinder anti-rotation plate and the jack
front access cover. Do not touch or grab the anti-rotation
rods. Do not place hands in or on the cylinder protective
bellows. Serious personal injury can occur if cylinder is
lowered and hands, fi ngers or other body parts are present in
these areas. See Figure 1.
Figure 1, Pinch Point Hazard
Crush and Pinch Point Hazard
Do not reach in this area!