3.

Installation & Setup

Installation and Setup provides directions for installing and connecting the Protocol Manager
software.

3.1. System Requirements

The control computer must meet these requirements:

Computer running Windows XP, Vista or Windows 7 (32 or 64-bit version) operating system

Despatch oven(s) equipped with Protocol Plus

and/or Protocol 3

firmware 2.3 or higher

controllers and communications hardware


The Installation and Setup procedures use the Protocol 3 and Protocol Plus Controller. Consult
the Protocol 3 Controller Owner’s Manual (E-105) or the Protocol Plus Controller Owner’s
Manual (E98) for more detail as needed.


3.2. Configure Controllers

Before completing the Protocol Manager software setup, set up each controller.

List the unique addresses that will be applied to each Protocol 3 or Protocol Plus controller,

numbered from 1-255

Locate each Protocol 3/Protocol Plus controller

3.2.1. Configure the Protocol 3 Controller

Assign a unique address to each controller and set other communication parameters. See the
Protocol 3 Controller Owner’s Manual (E-105, PN313327) for more information. Typical settings
include:
1. Enter the

Main Menu

2. Enter the

Configuration Menu

3. Enter

Comms Configuration

4. Set

Modbus Parity Bit

to

None

5. Set

Modbus Data Rate

to

19200

6. Set unique

Modbus Address

: from

1

to

255


“Profile” and “Recipe” are used interchangeably throughout
the Protocol 3, Protocol Plus, Protocol Manager to indicate
those instructions assigned to carry out certain processes.


Note that the Protocol 3 controller must be running firmware
2.3 or higher.