Installation & setup, System requirements, Configure controllers – Despatch Protocol Manager with Protocol 3 and Protocol Plus User Manual
Page 12: Configure the protocol 3 controller
I
NSTALLATION
&
S
ETUP
Protocol Manager Instruction Manual
12
Version 1
Copyright © 2013 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
3.
Installation & Setup
Installation and Setup provides directions for installing and connecting the Protocol Manager
software.
3.1. System Requirements
The control computer must meet these requirements:
Computer running Windows XP, Vista or Windows 7 (32 or 64-bit version) operating system
Despatch oven(s) equipped with Protocol Plus
and/or Protocol 3
firmware 2.3 or higher
controllers and communications hardware
The Installation and Setup procedures use the Protocol 3 and Protocol Plus Controller. Consult
the Protocol 3 Controller Owner’s Manual (E-105) or the Protocol Plus Controller Owner’s
Manual (E98) for more detail as needed.
3.2. Configure Controllers
Before completing the Protocol Manager software setup, set up each controller.
List the unique addresses that will be applied to each Protocol 3 or Protocol Plus controller,
numbered from 1-255
Locate each Protocol 3/Protocol Plus controller
3.2.1. Configure the Protocol 3 Controller
Assign a unique address to each controller and set other communication parameters. See the
Protocol 3 Controller Owner’s Manual (E-105, PN313327) for more information. Typical settings
include:
1. Enter the
Main Menu
2. Enter the
Configuration Menu
3. Enter
Comms Configuration
4. Set
Modbus Parity Bit
to
None
5. Set
Modbus Data Rate
to
19200
6. Set unique
Modbus Address
: from
1
to
255
“Profile” and “Recipe” are used interchangeably throughout
the Protocol 3, Protocol Plus, Protocol Manager to indicate
those instructions assigned to carry out certain processes.
Note that the Protocol 3 controller must be running firmware
2.3 or higher.