2 event log – Atop Technology EH7510 User manual User Manual
Page 93
![background image](/manuals/554947/93/background.png)
Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
87
Table 2.57
Label
Description
Factory
Default
Enable Log Event to
Flash
Checked: Saving log event into flash memory.
The flash memory can keep the log event files
even if the switch is rebooted.
Unchecked: Saving log event into RAM
memory. The RAM memory cannot keep the log
event files after each reboot.
Uncheck
Log Level
Set the log level to determine what events to be
displayed on the next page (Event Log). Level
selected is inclusive.
For example, if 3 :(Log_ERR) is selected, all 0,
1 , 2 and 3 levels will be implied.
3: (LOG_ERR)
Enable Syslog Server
Checked: Enable Syslog Server.
Uncheck: Disable Syslog Server.
If enabled, all log events recorded will be sent to
the remote Syslog server.
Uncheck
Syslog Server IP
Set the IP address of Syslog server
0.0.0.0
Syslog Server Service
Port
Set the service port number of Syslog server
514
2.17.2 Event Log
Fig. 2.78