Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
66
DIP 1 and 2 definition:
Table 2.41
DIP Switch
Off
On
1
Ring is deactivated
Ring is activate
2
Slave
Master
DIP 3 and 4 definition:
Table 2.42
DIP Switch 3
DIP Switch 4
Ring Type
Off
Off
Select ERPS
Off
On
Select iA-Ring
On
Off
Select Compatible-Ring (only slave mode is
supported)
Factory default setting:
o DIP Switch 1: OFF (Ring is inactive)
o DIP Switch 2: OFF (Slave is selected)
o DIP Switch 3/4: OFF/OFF (ERPS is selected)
DIP switch 1 must be set to the “ON” position to enable DIP switches 2, 3, and 4. If
DIP switch 1 is set to the “OFF” position, then DIP switches 2, 3, and 4 will all be
disabled.
When DIP 1 is set to “ON”, the default ring ports are Port9 and Port10 (Port10 is
RPL port).
When the Compatible-Ring is selected, DIP 2 is unused.
For example, if users want to set this device to be a master in an ERPS Ring, DIP switch 1
and 2 should be on, and DIP switch 3 and 4 should be off. These settings define the device
to be a master with Port10 being RPL in an ERPS ring.