69
ERPS settings are shown on Fig. 2.57; users should disable the DIP Switch Control first in
order to set up ERPS parameters.
Table 2.44
Label
Description
Factory Default
ERPS
Choose whether to enable ERPS or not.
Disabled
Log
Choose to enable log.
Enabled
UERPS
Choose whether to enable UERPS.
When UERPS is enabled, ring ports periodically
sent a “heartbeat” packet to peer ring ports in order
to determine whether the link path (etc. wireless
bridge) is failure or alive.
If peer ring port
cannot receive “heartbeat”
packets over 3 packets, the ring port will enter
protection state.
Note: This function affect the recovery time to
more than 20 ms.
Disabled
Heartbeat Interval
Set the Heartbeat Interval.
Range from 50 to 10000 milliseconds.
500 ms
RAPS VLAN
Create the ring by specifying the R-APS VLAN ID of
the ring.
VLAN ID ranges from 1 to 4094.
None
After enabling the ERPS and adding a RAPS VLAN, users can click on
for
more details and configurations, which are shown on Fig. 2.58.
Fig. 2.58