7 modbus setting, 6 system time and sntp – Atop Technology EH7510 User manual User Manual
Page 26
![background image](/manuals/554947/26/background.png)
Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
20
2.3.6 System Time and SNTP
Fig. 2.14
This option, (Fig. 2.14) configures EH7510 time and date; it also supports Daylight Saving
Time and SNTP (See notes below for explanation).
Table 2.9
Label
Description
Factory Default
Current Date Allows local date configuration in yyyy/mm/dd format
None
Current
Time
Allows local time configuration in local 24-hour format.
None
System
Startup Time
Indicates how long the switch has been working.
Dependant
Daylight
Saving Time
Start Date: defines the start date of daylight saving.
End Date: defines the end date of daylight saving.
Offset: decide how many hours to be shifted
forward/backward when daylight saving time begins and
ends. See note below.
None
Enable
SNTP
Enables SNTP function. See note below.
Unchecked
NTP Server
1
Sets the first IP or Domain address of NTP Server.
time.nist.gov
NTP Server
2
Sets the second IP or Domain address of NTP Server.
Switch will locate the 2nd NTP Server if the 1st NTP
Server fails to connect.
Time-
A.timefreq.bldrdoc.gov
Time Zone
User’s current local time.
(GMT+08:00)Beijing,
Chongqing, Hong Kong
Time Server
Query
Period
This parameter determines how frequently the time is
updated from the NTP server.
259200 seconds.
Note:
- Daylight Saving Time: In certain regions (e.g. US), local time is adjusted during summer
season in order to provide an extra hour of daylight in the afternoon, and the time shifted