2 alert warning events – Atop Technology EH7510 User manual User Manual
Page 87
Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
81
Table 2.53
Label
Description
Factory
Default
Port
Indicates the port number.
Port state event
Disable: Disables alarm function, i.e. no alarm
message will be sent.
Link Up: Alarm message will be sent when this
port/link is up and connection begins.
Link Down: Alarm message will be sent when this
port/link is down and disconnected.
Link Up /Down: Alarm message will be sent
whenever there’s a change, i.e. connection begins or
connection disrupted.
Disabled
Table 2.54.a
Label
Description
Factory
Default
Power
Indicates specific power supply.
Power status event
Disable: Disables alarm function.
Power On: Sends an alarm when power is turned on.
Power Off: Sends an alarm when power is turned off.
Disabled
Table 2.54.b
Label
Description
Factory Default
System log event
Disable: Disable power status detection.
0: (LOG_EMERG): Enable log level 0~7 detection.
1: (LOG_ALERT): Enable log level 1~7 detection.
2: (LOG_CRIT): Enable log level 2~7 detection.
3: (LOG_ERR): Enable log level 3~7 detection.
4: (LOG_WARNING): Enable log level 4~7 detection.
5: (LOG_NOTICE): Enable log level 5~7 detection.
6: (LOG_INFO): Enable log level 6~7 detection.
7: (LOG_DEBUG): Enable log level 7 detection.
See note below for specific log level description.
Disabled
*NOTE:
- Log levels are inclusive. In other word, when log level is set to 0, alarm is triggered
whenever 0, 1, 2… 6, and/or 7 happen. When log level is set to 5, alarm is triggered
whenever 5, 6, and/or 7 happen.
0: Emergency: system is unstable
1: Alert: action must be taken immediately
2: Critical: critical conditions
3: Error: error conditions
4: Warning: warning condition
5: Notice: normal but significant condition
6: Informational: informational messages
7: Debug: debug-level messages