14 lldp, 1 lldp – Atop Technology EH7510 User manual User Manual
Page 83
![background image](/manuals/554947/83/background.png)
Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
77
U-ring protocol could be used in the above environment, the AP
x
could be:
Dump-switch
Transceiver
XDSL bridge
Care should be taken that if a dump-switch is used as an AP (Access Point) the one in the
other side must be a dump-switch as well; again care should be taken when connecting the
cables to the ports.
The main screen will look as follows.
Fig. 2.69
Table 2.50
Label
Description
Factory Default
Operation Status
Shows whether the device’s state is normal or
protected.
Dependant
1
st
Ring
Port
Status
Displays the 1
st
ring port’s status.
Forwarding
2
nd
Ring
Port
Status
Displays the 2
nd
ring port’s status.
Forwarding
U-Ring
Shows whether the Unicast ring is working.
Disabled
Ring Master
Shows whether the device is a slave or master on
this ring. For Slave option leave it as disabled.
Disabled
1
st
Ring Port
Displays whether this Ethernet port is being used for
the corresponding ring’s port.
Port 1
2
nd
Ring Port
Displays whether this Ethernet port is being used for
the corresponding ring’s port.
Port 2
Heartbeat Expire
Time interval between checking-packets.
1000