2.4.3 Port Control
Port settings are included to give users control over State (enabled or disabled), Port
Transmission Speed, Duplex, Flow Control, Rate Control and Throughput Test.
Fig. 2.23
Table 2.12
Label
Description
Factory Default
Port
Port number on the switch.
Enable
Check the box to allow data to be transmitted and
received through this port.
All ports are enabled
Negoti
ation
Choose from Force or Auto. See notes below.
All ports Auto- Negotiation
is enabled.
Speed
Select either 10, 100,1000(Port 9, 10 only) Mbps
Port1~Port8: 100Mbps.
Port9, Port10: 1000Mbps.
Duplex
Select either Half or Full Duplex. See note below.
All ports are Full-Duplex
mode.
Flow
Control
Either on or off
“Flow Control” to avoid packet
loss when congestion occurs.
All ports flow control is
disabled.
Rate
Control
Sets limits on its transmission rate for the
incoming and outgoing. Unit: kbps
All ports rate control is
disabled.
Throughput
Test
Click
button to start test ingress and
outgoing rate of this port.
Note: The maximum rate test is limited under
98Mbps.
-
*Note:
- Rate Control: Outgoing and incoming values have to be set between 0 and 102400(for
100M) or 1024000(for 1000M)..
0 is to turn off rate control.
The values have to be integer multiples of 64 when rate is less than 1792Kbps. Ex: 64k,
128k .. 512k
…1792Kbps.