beautypg.com

13 operation, Positioning of the labels – Brady PAM 3000 User Manual

Page 44

background image

Printer-Applicator-System PAM 3000

44

13 Operation

Positioning of the Labels

The labels could be applied parallel to the print line (0°-position) as well as across to the print

line (90°-position). An external signal via PLC interface triggers the type of labelling (see

appendix C). The take-over of the labels is carried out in the 0°-position for both types of

applying. The following movements are different :

0°-Applying

1. Turning into the 90°-position

2. Moving down

3. Stop

4. Turning into the 0°-position

5. Moving down

6. Applying

7. Moving up

8. Stop

9. Turning into the 90°-position

10. Moving up

11. Turning into the 0°-position

90°-Applying

1. Turning into the 90°-position

2. Moving down

3. Stop

4. not any movement

5. Moving down

6. Applying

7. Moving up

8. Stop

9. not any movement

10. Moving up

11. Turning into the 0°-position

Fig. 13a Sensors

The stop is set during the movement process to guarantee a correct carrying out of the turning

of the pad. The location of the stop depends on the setting of the sensors (1, 2). During the

90°-applying the stop is not recognized by the user.

2

1