beautypg.com

Special settings for the operation – Brady PAM 3000 User Manual

Page 34

background image

34

Printer-Applicator-System PAM 3000

Special Settings for the Operation

There are integrated four DIP-switches to determine several types of operation. The DIP-

switches are located in the opening (1) at the right side of the printer.

Fig. 8e

DIP-switches

1

DIP-switch

Parameter

ON

OFF

1

Label format

small

large

2

Recycle part

not installed

installed

3

Applicator

installed

not installed

4

Print repeat

no

yes

DIP-switch 1-This switch is set on "ON" when small labels are used. By using large labels

the switch has to set on "OFF".

DIP-switch 2- If the switch is set on "ON" it is not possible to dispose the bad labels

recognized by a scanner at a recycle part.

If the switch is set on "OFF" it is possible to apply the bad labels on the recycle

part.

It is recommended to set the switch always on "ON" if no scanner is used.

DIP-switch 3- If the switch is set on "ON" the printer notices that there is an applicator to carry

out the further steps after printing.

If the switch is set on "OFF" it is necessary to guarantee the correct further

processing of the applying process by other features for example manually or

by industrial robots.

DIP-switch 4- If the switch is set on "ON" a bad label recognized by a scanner will not printed

again.

If the switch is set on "OFF" the print of a bad label recognized by a scanner

will be repeated.

It is recommended to set the switch always on "ON" if no scanner is used.