Printer-Applicator-System PAM 3000

10 Setup

Using the setup mode, the configuration of the PAM 3000 may be customized to suit specific

requirements. Initial setup should be performed when operating the printer for the first time.

Changes which become necessary to process different print jobs, e.g. when different

materials are used, can mostly be accomplished by changing the software settings.

Start of Setup Mode

This mode is initiated by either simultaneously pressing down the

key and the

key

when switching on the printer and keep them pressed until the system test is completed, or in

ONLINE mode, press the same two keys down for at least 5 seconds.

Starting the setup mode, the display shows "SETUP" for about one second, followed by

"Country" which represents the first of the parameters to select from. Depending on the

selection, the setup parameters and their settings will be shown. The list of parameters is

brought up in a row and may be run through repeatedly.

Each time a parameter setting has been changed, there will be a request for confirmation.

There will not be a general request before leaving the setup mode.

Leaving the Setup Mode

The setup mode can be left at any point by pressing the

key. The confirmed parameters

will be saved.

If an already confirmed setting is not desired any more, switch off the printer during the setup

mode to cancel changes.

Restore the Default Setting

To return to the original factory default settings, press all three keys, the

key, the

key,

and the

key simultaneously while switching on the printer and keep them pressed down

until the display shows "--- RESTORE ---".

Function Keys in System Mode SETUP

ONL key

Stores the chosen and confirmed settings of the setup-parameters and

completes the SETUP mode.

(i.e. switch into ONLINE mode (LED ONL on)

FF key

Skips to next setup parameter.

Reduces numerical setup values.

CAN key

Skips to previous setup parameter.

Increases numerical setup values.

PSE key

Confirms selected settings for parameters.