beautypg.com

Connection to power supply – Brady PAM 3000 User Manual

Page 27

background image

27

Printer-Applicator-System PAM 3000

Fig. 6c

Power supply module

Connection to Power Supply

1

2

3

4

The PAM 3000 is designed for use with 230V A.C/ 50Hz (standard) or 115V A.C/60Hz.

CAUTION !

Before connecting the printer to the power supply, make sure that the voltage

selected on the power supply module of the printer is the same as your main

power supply !

1 - Voltage selector

2 - Voltage selector cover

3 - Power switch

4 - Power supply connector

To change the voltage setting, open the cover (2) and remove the voltage selector from the

power unit.

CAUTION !

If you have changed the operating voltage of your printer the fuses need replacing

as stated below !

230 V - 2 x T 1.5 A

115 V - 2 x T 3 A

When delivered, the correct fuses for the pre-selected operative voltage are installed. You will

find the necessary fuses for the other voltage in the accessories package.

Slide the voltage selector back into the power supply module so that the correct voltage is

visible in the lid window.

Connect the printer to a grounded outlet using the power cable supplied in the accessories

package.