2N Lift8 v1.0 User Manual
Page 66

66
tone is considered to be
the sum of sections
between which there is no
long gap. The longest gap
in the period of ringing
must be in an interval
between the parameters
952 and 953.
NOTA BENE! parameters
951 - 3 function (defaults)
for incoming ringing.
952
Min. period of
long gap of
dialling tone
100 – 5000 ms
1000 ms
953
Max. period of
long gap of
dialling tone
500 – 9999 ms
6000 ms
961
Max. time to
press next
numeral
15 – 120 s
60 s
Counted from the
transition to the new state
(NOT after end of
announcement)
962
Min. period of
pressing of
ALARM button
of announcer in
the cabin
10 – 9999 ms
100 ms
A short value is configured
due to comfortable testing
of the product
968
Period of
ringing to
machine room
(siren)
1 – 60 s
1 s
969
Time of ringing
to intercom
1 – 60 s
1 s
973
Language for
numerical
announcements
0 - 1
1
0 = recorded by user
1 = language of voice
menu
974
Identification of
lift
max. 16 numerals 0
- 9
empty
Allows identification of lift
if there is a foreigner in it
for example. If not filled
in, the serial number is
used.
975
Sequence of
announcements
to cabin
(Alarm)
max. 8
announcements in
a row
empty
(=22)
It allows playing back
messages in more
languages in the defined
sequence, including the
identification number, etc.
01 = User message #1
02 = User message #2
03 = User message #3
04 = User message #4
05 = User message #5
06 = User message #6