Before you start, Connecting usb port – 2N Lift8 v1.0 User Manual
Page 23
23
Reset equipment
– press button quickly.
Restoration of factory settings
– press button and hold until all the LEDs
light up red. Then release and wait until SYSTEM LED flashes yellow. Now press
button quickly. All the user settings will now be deleted.
Zeroing the counter of backup rechargeable battery life
– press button
and hold until all the LEDs light up red. Then release and wait until
POWER/BATTERY LED flashes yellow. Now press button quickly. Only perform this
function after replacing the backup rechargeable batteries with new ones!
Configuration of system completeness
– press button and hold until all the
LEDs light up red. Then release and wait until INTERNAL BUS LED flashes yellow.
Now press button quickly. From this moment the system will supervise whether
all the installed equipment (splitters, announcers etc.) are connected and
functional.
Complete deletion of central unit's software
– press button and hold until
all the LEDs light up red. Then release and wait until SYSTEM LED flashes red.
Now press button quickly. NOTA BENE, after performing this function it is only
possible to restore the equipment's normal function using a PC!
Connecting USB port
Recommendation:
Unless necessary do not leave connected to a computer long term. This will
reduce the risk of damage to the computer in the case of a voltage surge from
the telephone line, for example during a storm
Before you start
Conditions for installation of CU:
The central unit (referred to hereinafter as CU) is not intended for outdoor
use.
Do not install the CU on a machine or construction which is a source of
vibrations.
In order to ensure sufficient cooling free access to air must be ensured for the CU
must (it is forbidden to cover the CU, for example with a rag, or to install it in
another enclosed box).
Installation in the lift switchbox is possible if the air temperature in the this box
does not exceed the permitted limits. Remember that a higher air temperature
reduces the lifespan of backup rechargeable batteries in the CU.
It is recommended that the CU be operated in the upright position with the cable
openings at the bottom. Such a mounting makes it possible to ensure the lowest
temperatures of the rechargeable batteries and thus their longest life. Horizontal
mounting is also possible. The upright position with the cable openings at the
top (upside down) is forbidden!
After mounting the CU check that the equipment is firmly fixed in place and that
it cannot come loose and drop down the shaft.
Warning
Do not open the CU
during the warranty period .
After the warranty period open it only to change the rechargeable
batteries.