2N Lift8 v1.0 User Manual
Page 65

65
913
Time limit of
login
10 – 1000 s
60 s
Max. period during which
the control centre worker
must pick up the call and
send a confirmation,
otherwise L8 hangs up and
continues with dialling of
next number. Counted
from the end of dialling.
914
Delayed call
0 – 1000 s
0 s
Used only with connected
entry CANCEL on
announcer in cabin
915
Max. period
TRIPHONY
10 – 9999 s
7200 s
917
Time of
hanging up
between calls
500 – 9999 ms
5000 ms
918
Max. period of
telephone line
test
1 – 20s
5 s
Test of line (the dialling
tone is tested) is
performed each 11
minutes. If no dialling tone
is present three times in a
row, the lift is blocked. As
soon as the line is in
operation again, the lift is
unblocked automatically.
940
Min. period of
dialling tone
200 – 2000 ms
400 ms
The tone must be longer
than a half-period of busy
tone!
941
Min. period of
constant tone
200 – 9999 ms
2000 ms
If the tone lasts long, LN
hangs up.
942
Min. period of
busy tone
100 – 500 ms
200 ms
These parameters can
correct the detection of
the busy tone.
944
Max. difference
of tone – gap
10 – 400 ms
50 ms
945
Min. number
period of busy
tone
2 - 50
5
948
Min. period of
dialling tone
50 – 2000 ms
200 ms
Period of dialling tone is
the length of the section
just before the long gap
949
Min. period of
long gap of
dialling tone
(ring-back)
100 – 5000 ms
2500 ms
The longest gap in the
period of ringing must be
in an interval between the
parameters 949 and 950.
950
Max. period of
long gap of
dialling tone
(ring-back)
500 – 9999 ms
5500 ms
The longest gap in the
period of ringing must be
in an interval between the
parameters 949 and 950.
951
Min. period of
dialling tone
50 – 2000 ms
200 ms
Detection of incoming
call:
The period of the dialling