JLG 1500SJ Service Manual User Manual
Page 466

SECTION 6 - JLG CONTROL SYSTEM
6-14
– JLG Lift –
3121262
MAIN LIFT:
ACCEL X.Xs
Displays/adjusts main lift acceleration 0.1 to 5.0 sec
1
DECEL X.Xs
Displays/adjusts main lift deceleration 0.1 to 3.0 sec
1
MIN UP XX%
Displays/adjusts minimum main lift up
speed
0 to 60%
20
MAX UP XX%
Displays/adjusts maximum main lift
up speed
0 to 100%
60
75-100 (see orientation)
CREEP UP XX%
Displays/adjusts maximum main lift
up speed
0 to 65%
50
NOTE: used when creep switch on
pump pot is active
MIN DOWN XX%
Displays/adjusts minimum main lift
down speed
0 to 60%
10
MAX DOWN XXX%
Displays/adjusts maximum main lift
down speed
0 to 100%
60
85-110 (see orientation)
CREEP DOWN XX%
Displays/adjusts maximum main lift
down speed
0 to 75%
45
NOTE: used when creep switch on
pump pot is active
SWING:
ACCEL X.Xs
Displays/adjusts swing acceleration
0.1 to 5.0 sec
2
DECEL X.Xs
Displays/adjusts swing deceleration
0.1 to 3.0 sec
1.5
MIN LEFT XX%
Displays/adjusts minimum swing left
speed
0 to 50%
40
MAX LEFT XXX%
Displays/adjusts maximum swing left
speed
0 to 100%
65
115-125 (see orientation)
CREEP LEFT XX%
Displays/adjusts maximum swing left
speed
0 to 65%
52
NOTE: used when creep switch on
pump pot is active
MIN RIGHT XX%
Displays/adjusts minimum swing right
speed
0 to 50%
40
MAX RIGHT XXX%
Displays/adjusts maximum swing
right speed
0 to 100%
60
115-125 (see orientation)
CREEP RIGHT XX%
Displays/adjusts maximum swing
right speed
0 to 65%
47
NOTE: used when creep switch on
pump pot is active
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)