Adjusting parameters using the hand held analyzer – JLG 1500SJ Service Manual User Manual
Page 456

SECTION 6 - JLG CONTROL SYSTEM
6-4
– JLG Lift –
3121262
Press ENTER
to select the ACCESS LEVEL menu.
Using the UP
or
DOWN
arrow keys, enter the
first digit of the password, 3.
Then using the RIGHT
arrow key, position the cur-
sor to the right one space to enter the second digit of the
password.
Use the UP
or DOWN
arrow key to enter the
second digit of the password which is 33271.
Once the correct password is displayed, press ENTER
. The access level should display the following, if the
password was entered correctly:
MENU:
ACCESS LEVEL 1
Repeat the above steps if the correct access level is not
displayed or you can not adjust the personality settings.
Adjusting Parameters Using the Hand Held
Analyzer
Once you have gained access to level 1, and a personality
item is selected, press the UP
or
DOWN
arrow keys to adjust its value, for example:
DRIVE:
ACCEL 1.5s
There will be a minimum and maximum for the value to
ensure efficient operation. The Value will not increase if
the UP
arrow is pressed when at the maximum
value nor will the value decrease if the DOWN
arrow
is pressed and the value is at the minimum value for any
particular personality. If the value does not change when
pressing the up and down arrows, check the access level
to ensure you are at access level 1.