2 machine personality settings and function speeds – JLG 1500SJ Service Manual User Manual
Page 465

SECTION 6 - JLG CONTROL SYSTEM
3121262
– JLG Lift –
6-13
6.2 MACHINE PERSONALITY SETTINGS AND
FUNCTION SPEEDS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)
DRIVE:
ACCEL X.Xs
Displays/adjusts drive acceleration
0.1 to 5.0 sec
2
DECEL X.Xs
Displays/adjusts drive deceleration
0.1 to 3.0 sec
1.3
MIN forward XX%
Displays/adjusts minimum forward
drive speed
0 to 35%
1
MAX forward XXX%
Displays/adjusts maximum forward
drive speed
0 to 100%
100
44-48 (see orientation)
MIN reverse XX%
Displays/adjusts minimum reverse
drive speed
0 to 35%
1
MAX reverse XXX%
Displays/adjusts maximum reverse
drive speed
0 to 100%
100
44-48 (see orientation)
ELEV. MAX XX%
Displays/adjusts maximum drive
speed
0 to 50%
25
93-104 (see orientation)
NOTE: used when elevation cutout
switches are limiting maximum speed
CREEP MAX XX%
Displays/adjusts maximum drive
speed
0 to 50%
35
79-87 (see orientation)
NOTE: used when creep switch on
pump pot is active
STEER:
MAX SPEED XXX%
Displays/adjusts maximum steer
speed.
0 to 100%
100