Environmental specifications

The following specifications identify maximum environmental conditions. At no time
should the server run under conditions which violate these specifications.

Variable

Requirements

Temperature

Maximum rate of change: 18°F (10°C) per hour

Nonoperating: -4° to 140°F (-20° to 60°C)

Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters)

Altitude

12,500 feet (3,810 meters) maximum

Humidity

Operating: 20% to 80% relative, non-condensing

Nonoperating: 20% to 90% relative non-condensing at 86° F (30° C)

Shock

Operating: 2.0 g, 11 msec, ½ sine

Packaged: Operational after 18-inch free fall (cosmetic damage might
occur)

AC input power

100-127 V, 10.0 A, 50/60 Hz max.

200-240 V, 5.0 A, 50/60 Hz max.