Environmental specifications
The following specifications identify maximum environmental conditions. At no time
should the server run under conditions which violate these specifications.
Variable
Requirements
Temperature
Maximum rate of change: 18°F (10°C) per hour
Nonoperating: -4° to 140°F (-20° to 60°C)
Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters)
Altitude
12,500 feet (3,810 meters) maximum
Humidity
Operating: 20% to 80% relative, non-condensing
Nonoperating: 20% to 90% relative non-condensing at 86° F (30° C)
Shock
Operating: 2.0 g, 11 msec, ½ sine
Packaged: Operational after 18-inch free fall (cosmetic damage might
occur)
AC input power
100-127 V, 10.0 A, 50/60 Hz max.