The disk and sts indicators light and flash amber, The fault indicator lights amber, The fdd indicator does not light – Toshiba Magnia Z300 User Manual
Page 231
Troubleshooting
Troubleshooting
209
The power indicator on this server lights with the power cord con-
nected to the AC outlet or while the server is in the power save
mode in the case of Windows 2000.
See “System status indicators” on page 14/page 114/page 129.
See “HDD/LAN status indicators” on page 19/page 115.
The disk and STS indicators light and flash amber
A probable cause is that a hard disk drive connected to the RAID
controller is malfunctioning. If Windows NT/2000 can be used
after checking from the lit state of the disk status indicators which
hard disk drive is malfunctioning, see “Remedy When Windows
NT/2000 is Usable” on page 214.
If Windows NT/2000 cannot be used, see “Remedy When Win-
dows NT/2000 is Unusable” on page 215.
See “HDD/LAN status indicators” on page 19/page 115.
See “Hard Disk Drive (HDD) –IDE HDD–” on page 98.
The fault indicator lights amber
A probable cause is that the cooling fan or power unit is malfunc-
tioning. Check whether or not Windows NT/2000 is usable. If
Windows NT/2000 can be used, see “Remedy When Windows
NT/2000 is Usable” on page 214.
If Windows NT/2000 cannot be used, see “Remedy When Win-
dows NT/2000 is Unusable” on page 215.
See “System status indicators” on page 14/page 114/page 129.
See “Power Supply Unit” on page 69.
The FDD indicator does not light
Probable causes are that the floppy disk drive unit signal cable is
not properly connected, or that the floppy disk drive unit itself is
malfunctioning. Check the signal cable connections. If this does
not remedy the problem, see “Remedy When Windows NT/2000
is Unusable” on page 215.