Configuration text files for unicenter, Unicenter configuration.txt – Konica Minolta BIZHUB C30P User Manual
Page 113
MetaConsole 2.3 including PageScope EMS Plug-Ins
page 99
Configuration Text Files for Unicenter
Configuration of MetaConsole server properties is governed by entries in a text file, configu-
ration.txt. The MetaConsole client has a corresponding properties file,console.properties.
Note
: Changes in console.properties do not take effect until you stop and restart the
Unicenter client.
Unicenter Configuration.txt
The configuration.txt file is created during installation and resides in the top-level installation
directory. If the file is not present, MetaConsole uses the default values, originally set at
installation time.
Configuration file entries have the form keyword=value. This section includes an example file
and a description of each keyword (including the keyword’s value when MetaConsole is
shipped).
Example File
#HTTP server port
Port=80
#HTTP server root directory
Root=root
#SNMP Providers - disabling/enabling sets
AllowWrites=True
#Service providers folder
ServiceProviderDirectory=mcsps
# whether logging to console is needed
LogToConsole=true
# whether logging to a stream (file) is needed
LogToFile-false
# file to log to
LogFile=MetaConsole.log
#whether file logged to is appended or rewritten
AppendToFile=false
# start page for the MetaConsole server, start page must
#be in the root for the server
StartPage=start.html
# will log HTTP query type and client IP address for all
#connections
LogClientIP=false