10 authentication unit (biometric type), 1 using an authentication unit (biometric type), Authentication unit (biometric type) – Konica Minolta BIZHUB C360 User Manual
Page 216: Using an authentication unit (biometric type) -2, P. 10-2), (p, P. 10-2
bizhub C360/C280/C220
10-2
10.1
Using an authentication unit (biometric type)
10
10
Authentication unit (biometric type)
This chapter describes the Authentication Unit (biometric type) AU-101 or Authentication Unit (biometric
type) AU-102.
1. Authentication Unit (biometric type) AU-101
2. Authentication Unit (biometric type) AU-102
10.1
Using an authentication unit (biometric type)
The Authentication Unit (biometric type) AU-101 or Authentication Unit (biometric type) AU-102 is a "bi-
ometrics (biometric authentication)" system that scans finger vein patterns to perform personal authentica-
tion. Using the biometric authentication, you can log in to this machine where user authentication settings are
configured in order to execute a print job.
Place your forefinger straight so that your forefinger cushion slightly touches the hollow and protuberance
part of the scanning section. Secure your middle finger and thumb on the both sides of the authentication
unit to prevent your forefinger to be used for authentication from rotating.
For details on how to place your forefinger on the authentication unit, refer to page 10-18.
NOTICE
If the Authentication Unit (biometric type) AU-101 is changed to the Authentication Unit (biometric type)
AU-102, the users registered in the Authentication Unit (biometric type) AU-101 cannot be used in the Au-
thentication Unit (biometric type) AU-102. Connect the Authentication Unit (biometric type) AU-102 to
this machine, and then register users again.
Do not place anything other than your finger on the scanning section during scanning operation. Doing so
may cause a malfunction.
Do not disconnect the USB cable from the authentication unit or computer during a scanning operation. Do-
ing so may cause the system to become unstable.
The status indicator LED and notice sound indicate the status of the authentication unit.
1
2
Status indicator LEDs
Status
Lit in green
Ready state or authentication is completed
Flash in green
During authentication or scanning operation
Lit in red
Authentication failed or scanning failed
Unlit
The authentication unit is not recognized
Notice sound
Status
One short blip sound
Scanning starts
One short blip sound
During a retry after authentication failed
One short blip sound
*1
/two short blip sounds
*2
Authentication completed
Two short blip sounds
*1
/
one short blip and one long beep sounds
*2
Authentication failed
One long beep sound
*2
Scanning canceled