9 [reset settings, Reset settings] -18 – Konica Minolta BIZHUB C360 User Manual
Page 155

bizhub C360/C280/C220
7-18
7.1
[System Settings]
7
7.1.9
[Reset Settings]
Configure auto reset settings.
0
All settings performed in the following tabs during operation using the copy function are automatically
reset to the initial settings after the specified time has elapsed.
[Basic], [Original Setting], [Quality/Density], [Application]
0
Even if [OFF] is selected for System Auto Reset Time, the system auto reset function operates when
this machine is not used for one minute during user authentication/account track operations.
%
Press the Utility/Counter key ö [Administrator Settings] ö [System Settings] ö [Reset Settings].
Factory default
[Job Settings List]
•
[1-Sided]
•
Tray 1
Settings
[System Auto Reset]
[Priority Mode]
Configure a mode to be displayed in the system
auto reset mode.
[System Auto Reset
Time]
Configure whether to perform system auto reset.
Specify a time until the initial screen appears if
this machine is not operated. The specified time
is not canceled.
d
Reference
If user authentication or enhanced se-
curity mode is enabled, the adminis-
trator settings mode or user
authentication mode is logged off ac-
cording to the setting for System Auto
Reset Time.
In the enlarge display mode, the sys-
tem auto reset mode is disabled.
[Auto Reset]
Configure whether to perform auto reset in the selected mode.
Specify a time until the basic settings screen appears and the settings are
reset to the initial values if this machine is not operated.
[Job Reset]
[When Account is
changed]
Configure whether to reset the settings when you
log off if the user authentication or account track
settings have been configured.
[When original is set
on ADF]
Configure whether to reset the settings when an
original is loaded in the ADF.
[Next Job]
Configure whether to reset the following settings
when the next job is selected.
•
[Staple Setting]
•
[Original Set/Bind Direction]
•
[Reset Data After Job]
The destination of data is always reset.