WIKA CF1H User Manual
Page 75
Operating Instructions Temperature Indicating Controller CF1H
V 1.2
•
01/2007
- 75 -
Character Item
Initial
Data
Scaling high limit setting
1370 °C
Scaling low limit setting
−200 °C
Decimal point place selection
No decimal point
PV filter time constant
0.0 seconds
Main output high limit setting
100 %
Main output low limit setting
0 %
Main ON/OFF action hysteresis
1.0 °C
Cooling action mode selection
Air cooling
Cooling output high limit
100%
Cooling output low limit
0%
Cooling ON/OFF action hysteresis
1.0°C
Alarm 1 action Energized/Deenergized
: Energized
Alarm 2 action Energized/Deenergized
: Energized
Alarm 1 hysteresis setting
1.0 °C
Alarm 2 hysteresis setting
1.0 °C
Alarm 1 delayed timer setting
0 seconds
Alarm 2 delayed timer setting
0 seconds
External setting high limit
400 °C
External setting low limit
0 °C
Transmission output selection
PV transmission
Transmission output high limit
400 °C
Transmission output low limit
0 °C
Display selection when control output is
off
Main setting value rising rate
0 °C/minute
Main setting value falling rate
0 °C/minute
Output selection when input burnout
: Turns the
control output off
Character Item
Initial
Data
Program control change
Fixed value control
Step 1 time setting
00.00
Step 2 time setting
00.00
Step 3 time setting
00.00
Step 4 time setting
00.00
Step 5 time setting
00.00
Step 6 time setting
00.00
Step 7 time setting
00.00