Kramer Electronics VP-747 User Manual
Page 60

VP-747 - VP-747 Communication Protocol
55
Set Commands (F = Function)
Control Type Function Param 1
Param 2
Param 3
Param 4 Description
Set
Get
0
-
242
-
-
-
-
Program Geometry
Diagonal Projection
Reset
0
1
243
-20 ~ 20
-
-
-
Program Geometry
Pincushion/Barrel
0
1
244
-180 ~ 180
-
-
-
Program Geometry
Rotation
0
-
245
-
-
-
-
Program Geometry
Reset all
0
1
271
0: Cut
1: Fade
2: Diagonal
3: Wipe
4: Circle
5: Square
6: Corner
7: Chessboard
-
-
-
Transition Effect
0
1
272
0:Swap
1:Follow
-
-
-
Transition Mode
0
1
273
1 ~ 5
-
-
-
Transition Speed
0
1
274
0 = no damping
1 = damping with a
maximum jump size of
10 steps
2 = damping with a
maximum jump size of
5 steps
3 = damping with a
maximum jump size of
3 steps
4 = damping with a
maximum jump size of
2 steps
Transition Damping
0
1
275
0: Top left
1: Bottom left
2: Top right
3: Bottom right
-
-
-
Transition Effect Option
- Diagonal
0
1
276
0: Left to right
1: Right to left
2: Up
3: Down
-
-
-
Transition Effect Option
- Wipe
0
1
277
0: In
1: Out
-
-
-
Transition Effect Option
- Circle
0
1
278
0: In
1: Out
-
-
-
Transition Effect Option
- Square
0
1
279
0: Top left
1: Bottom left
2: Top right
3: Bottom right
-
-
-
Transition Effect Option
- Corner
0
1
280
0: In
1: Out
-
-
-
Transition Effect Option
- Chessboard
0
-
281
-
-
-
-
Transition Take
0
1
282
0: Off
1: On
T-Bar Optimization
0
1
283
16 ~ 240
Checksum
-
-
T-Bar Command
Checksum Rule:
1. Set Command Only
2. Checksum = (Control
Type + Function +
Param1) % 256
3. Example : Y 0 283
100 127