Setting
Function
Default
Misc. Settings
(cont.)
HDCP Setting: Follow Input, Follow Output
Define whether the HDCP follows the input or the
output
When Follow Input is selected, the Scaler changes its HDCP
output setting (for the HDMI output) according to the HDCP of
the input. This option is recommended when the HDMI Scaler
output is connected to a splitter/switcher (in this mode,
switching may not be glitch-free)
When Follow Output is selected, the Scaler matches its HDCP
output to the HDCP setting of the HDMI acceptor to which it is
connected. This ensures smooth switching, regardless of the
input
Follow Output
Auto Image: Manual or Auto
Manual
Mode Set
Mode 1: 1400x1050@60Hz or 1680x1050@60Hz
1680x1050x60Hz
Mode 2: 1280x1024x75Hz or 1280x1024@76Hz
1280x1024x75Hz
Mode 3: 1280x768@60Hz or 1366x768@60Hz
1280x768x60Hz
Save
Save profile: from 1 to 8 (see
Section 8.1.5.1
Recall
Recall profile: from 1 to 8
Erase
Erase profile: from 1 to 8 or all
Factory reset
8.1.5.1 Save Lock
The Save Lock qualifies the Panel Lock. When set to On, the status of the Panel
lock is saved on power down, and then recalled when the unit is turned on again.
For a description of how to lock the front panel using the PANEL LOCK button, see
Section
If the Save Lock is OFF, the Panel Lock is OFF when the machine is powered up (even if the
Panel Lock was ON before the power was turned OFF).
8.1.5.2 Input Lock
The Input Lock qualifies the Panel Lock. When set to On, the 8x2 Input buttons
and the TAKE button are included in the buttons which are locked when the Panel
Lock is on.
If the Input Lock is ON, access to the front panel buttons is blocked when Panel Lock is On,
including the PROGRAM and PREVIEW INPUT selector front panel buttons, and the Program
and Preview IR remote transmitter keys. When Input Lock is Off, then you can still access the
8x2 Input buttons and the TAKE button, even if the Panel Lock is On.