Setting a timeout value, 6hwwlqj d 7lphrxw 9doxh – Allied Telesis AT-S31 User Manual
Page 48

Configuring the Omega Interface
48
6HWWLQJ D 7LPHRXW 9DOXH
Specifying a timeout value prevents unauthorized use of the Omega
interface in the event you forget to exit the Omega interface and leave
your management station unattended. By specifying a timeout value,
the program will end the session if there has been no management
activity after the timeout value has expired. The default for the timeout
value is 5 minutes.
To enter a new timeout value, perform the following procedure:
1. From the Main Menu, choose System Configuration.
The System Configuration Menu is displayed.
2. Select Omega Options.
The Omega Options Menu is displayed.
3. Select Timeout and enter a value from 0 (zero) to 32,767 (in minutes).
Entering a value of 0 means there is no timeout. The Omega interface
will not automatically end any session. A session is ended only if you
end the session yourself. If you enter 0, you must always properly quit
after a management session in order not to block subsequent remote
sessions and software downloads to the switch.
4. Press
The new Omega timeout value is now active.
5. Return to the Main Menu.