beautypg.com

Allied Telesis AT-9724TS User Manual

Page 100

background image

3.

After changing the route preference value for a specific routing protocol, that protocol needs to be restarted because the previously learned routes

have been dropped from the Switch.The Switch must learn the routes again before the new settings can take effect.

To view the Route Preference Settings window, click Configuration > Layer 3 IP Networking > Route Preference Settings:

Figure 6- 92. Current and New Route Preference Settings window

The following fields can be viewed or set:

Parameter

Description

RIP (1-999)

Enter a value between 1 and 999 to set the route preference for RIP.The lower the value, the higher the chance

the specified protocol will be chosen as the best path for routing packets.The default value is 100.

OSPF Intra (1-999)

Enter a value between 1 and 999 to set the route preference for OSPF Intra.The lower the value, the higher the

chance the specified protocol will be chosen as the best path for routing packets.The default value is 80.

STATIC (1-999)

Enter a value between 1 and 999 to set the route preference for Static.The lower the value, the higher the

chance the specified protocol will be chosen as the best path for routing packets.The default value is 60.

OSPF Inter (1-999)

Enter a value between 1 and 999 to set the route preference for OSPF Inter.The lower the value, the higher the

chance the specified protocol will be chosen as the best path for routing packets.The default value is 90.

OSPF ExtT1 (1-999)

Enter a value between 1 and 999 to set the route preference for OSPF ExtT1.The lower the value, the higher

the chance the specified protocol will be chosen as the best path for routing packets.The default value is 110.

OSPF ExtT2 (1-999)

Enter a value between 1 and 999 to set the route preference for OSPF ExtT2.The lower the value, the higher

the chance the specified protocol will be chosen as the best path for routing packets.The default value is 115.

Click Apply to implement changes made.

99

Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch