Starting a local management session, Chapter 2: installation 56 – Allied Telesis AT-MCF2000M User Manual
Page 56
Chapter 2: Installation
56
Starting a Local Management Session
To start a local management session on the chassis or
stack, perform the following procedure:
1.
Connect the DIN-8 connector on the RS-232
Serial Management cable included with the
AT-MCF2000M Management Module to the RS-232
Terminal port on the management module, as shown in
Figure 20.
Figure 20. Connecting the RS-232 Serial Management
Cable to the RS-232 Terminal Port
2.
Connect the DB-9 connector on the RS-232 Serial
Management cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3.
Configure the terminal or terminal emulation program
as follows:
Baud rate: 115200 bps (The baud rate of the
RS-232 Terminal port is adjustable from 9600 to
115200 bps. The default is 115200 bps. To adjust
the baud rate, refer to the AT-S85 and AT-S97
Management Software Command Line User’s
Guide.
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None