Chapter 2: Installation

56

Starting a Local Management Session

To start a local management session on the chassis or
stack, perform the following procedure:

1.

Connect the DIN-8 connector on the RS-232
Serial Management cable included with the
AT-MCF2000M Management Module to the RS-232
Terminal port on the management module, as shown in
Figure 20.

Figure 20. Connecting the RS-232 Serial Management

Cable to the RS-232 Terminal Port

2.

Connect the DB-9 connector on the RS-232 Serial
Management cable to an RS-232 port on a terminal or
PC with a terminal emulator program.

3.

Configure the terminal or terminal emulation program
as follows:

ˆ

Baud rate: 115200 bps (The baud rate of the
RS-232 Terminal port is adjustable from 9600 to
115200 bps. The default is 115200 bps. To adjust
the baud rate, refer to the AT-S85 and AT-S97
Management Software Command Line User’s
Guide
.

ˆ

Data bits: 8

ˆ

Parity: None

ˆ

Stop bits: 1

ˆ

Flow control: None