June 2004 Isis® Sonar User's Manual, Volume 2

132

I.3

Klein Digital Sonar System 2000

Isis can be interfaced to the Klein System 2000 digital sonar through the addition of two
optional components. The Klein 2000 server — a software upgrade, and
A digital connection to the DSP board (either PC31 or Chico board)
The discussion below also applies to the Klein T2100 transceiver.

I.3.1 Hardware

Setup

Isis connects to the Klein System 2000 by way of two cables. They are:

Klein 2000 Internal Cable with Select. This is a 37-pin, female D, short ribbon
cable (with bracket) going to a 40-pin IDC female header. A similar cable and
connectors are available for the Chico board.
Klein 2000 External Cable. This is a 37-pin, male-to-male D, round cable
approximately two meters long. It is wired in a straight-through configuration.

To connect the Klein 2000 to the Isis system

1. Power off the Isis and Klein systems.

2. Remove the cover to the Isis system.

3. Seat the 37-pin end of the Klein 2000 with Select Internal Cable into a

mounting bracket next to the components side of the DSP board’s mounting
bracket.

4. Firmly seat the 40-pin end of the Klein 2000 with Select Internal Cable into the

40-pin IDC female header on the DSP board. Look for the notation “JP15” below
the header to confirm that you are attaching to the proper header.

5. Insert the short internal cable so that pin 1 (red stripe edge) coincides with the

header’s markings.

6. Plug either end of the Klein 2000 External Cable to the 37-pin end of the

internal cable’s female connector.

7. Plug the remaining end of the Klein 2000 External Cable into the Klein 2000

sonar.

8. Replace the cover to the Isis system. You can power up the Isis and Klein

systems when you are ready.