BAUD RATE

Set the baud rate to match the other serial communications equipment on the

serial link. Normally, the baud rate is set to the highest value that all the serial
equipment are capable of transmitting and receiving.





ABBREVIATED PRINTING

Select



for full print or Command T transmissions (meter address,

parameter data and mnemonics) or



for abbreviated print transmissions

(parameter data only). This will affect all the parameters selected in the print
options. (If the meter address is 00, it will not be sent during a full transmission.)





PRINT OPTIONS



- Enters the sub-menu to select the meter parameters to appear during a

print request. For each parameter in the sub-menu, select



for that parameter

information to be sent during a print request or



for that parameter information

not to be sent. A print request is sometimes referred to as a block print because
more than one parameter's information (meter address, parameter data and
mnemonics) can be sent to a printer or computer as a block.

PARAMETER

DESCRIPTION

FACTORY

MNEMONIC



Rate A



RTA



Rate B



RTB



Rate C



RTC



Total A & B



TOA TOB



Total C



TOC



A B C Scale Factors



SFA SFB SFC



A B Count Load



LDA LDB



1 2 3 4 Setpoints *



SP1 SP2 SP3 SP4

*Setpoints are plug-in card dependent.



DATA BIT

Select either 7 or 8 bit data word lengths. Set the word length to match the

other serial communications equipment on the serial link.





PARITY BIT

Set the parity bit to match that of the other serial communications equipment

on the serial link. The meter ignores the parity when receiving data and sets the
parity bit for outgoing data. If no parity is selected with 7 bit word length, an
additional stop bit is used to force the frame size to 10 bits.



METER ADDRESS

Enter the serial meter (node) address. With a single unit, an address is not

needed and a value of zero can be used. With multiple units (RS485
applications), a unique 2 digit address number must be assigned to each meter.

7-SrL

bAUd

dAtA

PAR

PAr

Addr

Ab tot

Pro

C tot

SCFAC

CntLd

SPt

OPt

Abbr

NO

YES

Baud Rate

Meter

Address

Parity Bit

Data Bit

Print

Setpoint

Values

Print

Total A & B

Print

Count Load

Values

Print

Total C

Print

Scale Factors

Print

Options

Abbreviated

Printing

C rAtE

Print

Rate C

b rAtE

Print

Rate B

A rAtE

Print

Rate A

PAR

PARAMETER MENU

























to



6.7 MODULE 7 - S

ERIAL

C

OMMUNICATIONS

P

ARAMETERS

(



)

Module 7 is the programming module for the Serial Communications

Parameters. These parameters are used to match the serial settings of the meter
with those of the host computer or other serial device, such as a terminal or
printer. This programming module can only be accessed if an RS232 or RS485
Serial Communications card is installed.

This section also includes an explanation of the commands and formatting

required for communicating with the PAXDR. In order to establish serial
communications, the user must have host software that can send and receive
ASCII characters.

This section does NOT apply to the DeviceNet, Modbus, or Profibus-DP

communication cards. For details on the operation of the Fieldbus cards, refer
to the bulletin shipped with each card.