3 module 3 - d, Isplay, Rogram – Red Lion PAXDR User Manual

Page 15: Arameters

background image

15

15

6.3 MODULE 3 - D

ISPLAY

AND

P

ROGRAM

L

OCK

-

OUT

P

ARAMETERS

(



)

3-LOC

SP-n

COdE

Totalizer x

Display

Lockout

Totalizer x

Scale Factor

Access

Totalizer A

Count Load

Access

rAtE

Rate x

Display

Lock-out

PAR

tot

ACntLd

SCFAC

Pro

Setpoint 1-4

Access

Security

Code

x

x

x

Totalizer B

Count Load

Access

bCntLd

PARAMETER MENU

x = Rate or Totalizer A, B, and then C

= Setpoints 1 to 4

Module 3 is the programming for Display lock-out and “Full” and “Quick”

Program lock-out.

When in the Display Mode, the available displays can be read consecutively

by repeatedly pressing the DSP key. An annunciator indicates the display being
shown. These displays can be locked from being visible. It is recommended that
the display be set to



when the corresponding function is not used.

SELECTION

DESCRIPTION



Visible in Display Mode



Not visible in Display Mode

“Full” Programming Mode permits all parameters to be viewed and

modified. This Programming Mode can be locked with a security code and/or
user input. When locked and the PAR key is pressed, the meter enters a Quick
Programming Mode. In this mode, setpoint, count load and scale factor values
can still be read and/or changed per the selections below. The Display Intensity
Level () parameter also appears whenever Quick Programming Mode is
enabled, and the security code is greater than zero.

SELECTION

DESCRIPTION



Visible but not changeable in Quick Programming Mode



Visible and changeable in Quick Programming Mode



Not visible in Quick Programming Mode





RATE A B C DISPLAY LOCK-OUT

TOTALIZER A B C DISPLAY LOCK-OUT

These displays can be programmed for



or



.





















The setpoint values can be programmed for



,



, or



. Accessible

only with a Setpoint Plug-in card installed.





SETPOINT 1 to 4 ACCESS LOCK-OUT













to



Count Load values can be programmed for



,



, or



.

TOTALIZER A and B COUNT LOAD ACCESS LOCK-OUT









The Scale Factor values can be programmed for



,



, or



.





TOTALIZER A B C SCALE FACTOR ACCESS LOCK-OUT





Entry of a non-zero value will cause the prompt



to appear when trying to

access the “Full” Programming Mode. Access will only be allowed after entering
a matching security code or universal code of



. With this lock-out, a user input

would not have to be configured for Program Lock-out. However, this lock-out is
overridden by an inactive user input configured for Program Lock-out.

SECURITY CODE







PROGRAMMING MODE ACCESS

Throughout this document, Programming Mode always refers to “Full” Programming (all meter parameters are accessible), unless “Quick

Programming” is referenced.

SECURITY

CODE

USER INPUT

CONFIGURED

USER INPUT

STATE

WHEN PAR KEY IS

PRESSED

“FULL” PROGRAMMING MODE ACCESS

0

not



————

“Full” Programming

Immediate access.

>0

not



————

Quick Programming w/Display Intensity

After Quick Programming with correct code # at



prompt.

>0



Active

Quick Programming w/Display Intensity

After Quick Programming with correct code # at



prompt.

>0



Not Active

“Full” Programming

Immediate access.

0



Active

Quick Programming

No access

0



Not Active

“Full” Programming

Immediate access.