With OutBack Series/Parallel Stacking and the Master and Slave order established, check
the system:
• From the ADV/FX/STACK power save level slave adjust only screen, press the
soft key, and then the
• Verify the next screen is the power save level master adjust only screen.
• Press
the
• Turn on all FX output breakers.
• The Master FX’s INVERTER LED should be solid and all the Slaves INVERTER LEDs should be blinking.
• Adjust
the
power save level master adjust only from 0 to 1 by pressing the
Slave’s INVERTER LED go solid.
• When the INVERTER LED is on solid, the inverter is on. When the INVERTER LED on the Slave is blinking,
the FX is asleep.
• Press
the
Slave’s INVERTER LED turn on.
• Press
the
Slave’s INVERTER LED turn on.
• If you have more than three Slaves, keep increasing the value in the power save level master adjust only
screen and verify each Slave’s INVERTER LED comes on as expected.
• This check verifi es all FX Series Inverter/Chargers are stacked correctly.
• Adjust the power save level master adjust only down to 0.
ADV/FX/STACK----------P04
power save level 3
slave adjust only
DOWN INC DEC PORT
ADV/FX/STACK---------------
stacking setup 1
completed
TOP ADV MAIN
ADV/FX/STACK-----------P04
stack OB Slave L2
phase
DOWN INC DEC PORT
ADV/FX/STACK-----------P04
power save level 0
master adjust only
DOWN INC DEC PORT
ADV/FX/STACK---------- P01
power save level 0
master adjust only
DOWN INC DEC PORT
ADV/FX/STACK-----------P01
power save level 1
master adjust only
DOWN INC DEC PORT
PRESS TWICE
ADV/FX/STACK-----------P04
power save level 2
master adjust only
DOWN INC DEC PORT
ADV/FX/STACK-----------P01
power save level 3
master adjust only
DOWN INC DEC PORT
ADV/FX/STACK-----------P01
power save level 0
master adjust only
DOWN INC DEC PORT