Ranking the Slaves:

• From the last screen— ADV/FX/STACK P04—press the soft key twice to get into the power save

level slave adjust only menu. This menu allows you to set the order in which the Slave FXs come “ON”

• Press the soft key until P03 is displayed. The FX on Port 03 is the fi rst Slave that is in series (“OB

Slave L2”) with the Master. With this FX as the 1st rank Slave, both Legs turn “ON” directly, producing

240VAC without using the FW-X240. If you have a system that is diff erent from this example then press

the soft key until you get to a Slave FX that is in series (OB Slave L2) with the Master.

• If the screen’s factory setting is not set to 1—the 1st rank Slave—then press the soft key until it

becomes 1. Press the soft key until P02 appears. If you have a system that is diff erent from this

example then press the soft key until you get to a Slave FX that is in parallel (OB Slave L1) with

the Master.

• Press the soft key to change the power save level slave adjust only to 2, which is the 2nd rank Slave.

• Press the soft key twice until Port 04 is displayed. If you have a system that is diff erent from this

example then press the < PORT> soft key until you get to the next Slave FX that is in series (OB Slave L2)

with the Master.

• Press the soft key until the setting is 3 for 3rd rank Slave. Any additional FXs in the system can be

programmed by pressing the PORT soft key to get to the next FX and then press until the setting

is 4 for the 4th rank Slave. Continue this process, making sure each FX has its own slave ranking, until you

have set all FXs.

ADV/FX/STACK----------P04

stack OB Slave L2

phase

DOWN INC DEC PORT

ADV/FX/STACK-----------P04

power save level 1

slave adjust only

DOWN INC DEC PORT

ADV/FX/STACK----------P03

power save level 1

slave adjust only

DOWN INC DEC PORT

ADV/FX/STACK----------P02

power save level 1
slave adjust only

DOWN INC DEC PORT

ADV/FX/STACK----------P02

power save level 2

slave adjust only

DOWN INC DEC PORT

ADV/FX/STACK---------P04

power save level 1

slave adjust only

DOWN INC DEC POR

ADV/FX/STACK----------P04

power save level 3

slave adjust only

DOWN INC DEC PORT

PRESS TWICE