Stacking system examples – Outback Power Systems VFX Series Programming Manual User Manual
Page 38

37
Stacking System Examples
Dual-Stacked System Using Classic Stacking
• The system includes only two FXs and must be set up as described here.
• The bottom FX Series Inverter/Charger is plugged into Port 01 of the HUB and the next or second FX
is plugged into Port 02.
• Turn off all AC Output and AC Input breakers before powering up the FXs.
1. Press the
“stack 1-2ph master phase” screen appears.
2. Press the
3. Push the
Slave. This establishes the Slave 1 FX at Port 2 to be
in series with the Master at Port 1.
PRESS
THEN PRESS ENTER
4. Press the
to the MAIN screen.
ADV/PASSWORD-----------
enter the password
132
ENTER INC DEC EXIT
ADV/SETTINGS/WARNING
changes made could adversely
aff ect system performance
MAIN-------------------------
8:25:04A
SUM STATUS SETUP ADV
ADV/FX/PG2-----------------
choose category:
PG1 GRID GEN PG3
ADV/FX/PAGE 1-------------
choose category:
ADV INV CHGR PG2
ADV---------------------------
choose a device:
FX CC DC MATE
ADV/FX/STACK----------P02
stack Classic Slave
phase
DOWN INC DEC PORT
ADV/FX/STACK-----------P01
stack 1-2ph Master
phase
DOWN INC DEC PORT
ADV/FX/PAGE3--------------
choose category:
PG2 AUX STACK PG4