beautypg.com

Components and connections – Outback Power Systems VFX Series Programming Manual User Manual

Page 21

background image

20

AC Breakers Off

DC Breakers Off

Components and Connections

1. With all AC and DC breakers OFF, connect all FXs to the HUB with individual lengths of CAT5 cable.

a) Connect the OutBack MATE after all other components,

including any OutBack Charge Controllers, have been connected
and powered up.

b) Components installed after powering up the system will require

repolling the MATE (please see page 22).

c) With the MATE, a user assigns a status and stacking value to the

FX on each Port. These status and value assignments can be
changed at any time as long as the Master FX is plugged into
HUB Port 01.

• “1-2ph Master” for one and

two-phase systems

• “3ph Master” for a 3-phase

system

• The Master FX is always

considered to be the leg
one phase.

• GTFX and GVFX models

show “Master” not “1-2ph
Master” on the MATE
screen.

POWER

HUB

10

9

8

7

6

5

4

3

2

1

2

ND

Mate

1

st

Mate

• Slave FXs plug into Ports 02 and higher

• OutBack Charge Controllers plug into
any Ports after the last FX is connected.

The FX connected to Port
01 is always programmed
as the Master.

2

nd

MATE

Port is not
operable

MATE
connects
at 1st MATE
Port

BYPASS

OUTPUT

INPUT

NOTE: Pay attention to the Port number on the screen! Be sure the FX whose status and stacking value
you’re changing is the one you mean to change.

This manual is related to the following products: