Problem
Cause
Solution
AREA OFF Always
Displayed NOTE: The
AREA ON must be
displayed to count acres.
(cont)
Header sensor
installed backwards.
Refer to Installation Instruction. Ensure header
sensor is installed in the correct place with the
correct orientation (cable toward the rear of
combine, open end of black header sensor bracket
pointing towards ground).
Cable connections are
bad.
Disconnect cab, distribution and moisture sensor
cables and inspect pins for corrosion. Inspect the
cables for cuts or pinches. Reconnect cables and
check temperature again.
Header sensor bad.
Check resistance of the header sensor between
pins, A, B, and C on header sensor cable. Refer to
Reference Section for correct resistance readings.
Cable connections are
bad.
Disconnect cab, distribution and moisture sensor
cables and inspect pins for corrosion. Inspect the
cables for cuts or pinches. Reconnect cables and
check temperature again.
Header sensor bad.
Check resistance of the header sensor between
pins, A, B, and C on header sensor cable. Refer to
Reference Section for correct resistance readings.
Monitor Chirps While
Harvesting
Monitor is set on a
partial swath.
Display SWATH on the screen. Use the up/down
arrow keys to adjust to a full swath.
High Yield Reading
After Stopping
C1 value (calibration
number that
eliminates false grain
flow from vibration)
must be adjusted.
Refer to “Calibrating for Vibration (C1)” in
Calibration Section.
Incorrect Distance and
MPH
Calibration for
distance is incorrect
or not been down.
Refer to “Calibrating Distance” in Calibration
Section.
After you calibrate for distance, the monitor
automatically corrects any incorrect distance and
acres for previously harvested loads. NOTE: You
must calibrate the secondary speed sensor setting