Pf3000 pro, Direct drive – mark iii/mark iv, Ag leader technology – Ag Leader PF3000Pro Harvest & Application Operators Manual User Manual
Page 128: Application rate mode

Direct Drive – Mark III/Mark IV
PF3000 Pro
Application Rate Mode
Ag Leader Technology
July 2003
2-114
Material density: Set to product density in lbs/cubic feet of
product.
Conveyor rate: Set to the cubic feet/rev of applicator. This is the
CFR value in the New Leader manual. You usually have to enter
an initial value then check it or calibrate and fine-tune it for
accuracy. Refer to the New Leader manual for instructions on
how to do that procedure.
Maximum drive RPM: Set to 300 rpm unless otherwise advised.
This setting will be fixed at 240 rpm if you are using a MarkIII.
The Pro will not let the drive rpm get above this setting. A
message “SLOW DOWN!!” will be displayed every time the
maximum rpm is reached.
Drive Switch: Set this to INTERNAL to shut drive on/off using
switch on bottom right of Pro’s front panel. Set this to
EXTERNAL to turn drive on/off using optional remote switch on
MarkIV ver.2 and IV.4 drives.
Manual speed: Set this to your average speed if you are using
manual speed in place of your radar or GPS ground speed source.
Manual speed: Normally this should be set to OFF. The only
reason to set this to ON is if you can not get ground speed from
your radar or GPS or you want to run the drive in a stationary
position.
Fan speed pulses/rev: Set to number of pulses outputted by
spinner speed sensor per 1 revolution of fan. (New Leader’s
sensor is 4 pulses/rev)
3.
Press EXIT key to return to screen with ADVANCED SETTINGS
key. Press ADVANCED SETTINGS key.
Target Rate Outside Field: This only pertains to using a target
file.
Set to ZERO if want rate outside field to be zero.