Calibrating Distance

PF3000 Pro

(All Modes)

Ag Leader Technology

July 2003

3-2

Introduction

You must calibrate distance for a primary or secondary speed setting of
WHEEL, TRACK or RADAR.

Distance

To view the distance calibration screen press the:

Calibration

Screen

MENU key


CAL key

DISTANCE key

Choosing Speed
Sensor

You must choose the speed sensor you are using for ground speed before
you can calibrate distance. Use the UP or DOWN ARROW key to select
either:

WHEEL

TRACK

RADAR


Press the ENTER DISTANCE key after you have set the ground speed
sensor.


DISTANCE CALIBRATION

CHOOSE SENSOR:

WHEEL

ENTER

DISTANCE

EXIT