beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 70

background image

Index

70

MSA1000 Controller User Guide

firmware version

32

initializing fibre subsystem

59

initializing PCI subsystem

58

initializing SCSI devices

33

initializing SCSI subsystem

33

new volume(s) detected

50

no cache module found

40

no volumes detected

50

obsolete cache data deleted

42

PCI bridge ASIC self-test failure

58

PCI subsystem hardware failure

58

read failure

34

recovery ROM autoflash done

53

recovery ROM autoflash failed

53

recovery ROM autoflash started

53

redundancy active active Controller

35

redundancy active standby Controller

35

redundancy failed cache DIMMS mismatch

40

redundancy failed cache size mismatch

37

redundancy failed firmware lockup

38

redundancy failed hardware failure

35

redundancy failed I/O request error

39

redundancy failed mismatch firmware

36

redundancy failed mismatch hardware

36

redundancy failed no second Controller

39

redundancy failed out of memory

38

redundancy failed PCI bus error

39

redundancy halted firmware cloned

37

replacement drive found box

45

restarting system

33

ROM cloning done

54

ROM cloning failed

54

ROM cloning started

54

scanning for SCSI devices

33

SCSI subsystem hardware failure

33

smart drive alert box

45

startup complete

32

storage box

55

storage box EMU not responding

58

storage box EMU version

58

storage box fan failed

56

storage box fan hot inserted

56

storage box fan hot removed

56

storage box overheated

57

storage box overheating

56

storage box power supply added

57

storage box power supply failed

57

storage box power supply ok

57

storage box power supply removed

57

storage box temperature ok

56

storage fan degraded

56

system halted for cache error

43

system name

33

too many volumes detected

50

uncorrected ECC memory error seen

59

valid cache data found at power-up

40

volume expansion disabled

49

volume expansion failure

49

volume initializing parity

49

volume rebuild failure

49

volume state deleted

49

volume state disabled

47

volume state expansion active

47

volume state failed

47

volume state ok

47

volume state rebuilding

47

volume state waiting to expand

48

volume state waiting to rebuild

48

volume state wrong drive replaced

48

volumestate interim recovery

47

volumestate missing drives

48

write failure

34

conventions

document

7

equipment symbols

8

text symbols

7

D

document

conventions

7

documentation, related

6