beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 46

background image

Controller Display Messages

46

MSA1000 Controller User Guide

83 DRIVE HOT
REMOVED BOX
#, BAY

Informational

A SCSI drive has been

removed from the

MSA1000 or one of the

storage enclosures attached

to it.

84 DRIVE FAILURE
BOX #, BAY
84

Error

A SCSI drive in the

MSA1000 or one of the

storage enclosures attached

to it has failed. If the drive

was part of a configured

volume, then the state of

the volume will depend on

the fault tolerance used.

The drive should be

replaced as soon as

possible following the

guidelines in the

“Recovering from Hard

Drive Failure” section in

this guide (Appendix E).

85 BAD DRIVE
FRMWARE BOX
#, BAY

Error

A SCSI drive has been

detected that has known,

bad firmware on it.

Continued usage of this

drive could result in drive

failure, decreased

performance or data loss.

Either the drive firmware

should be updated or the

drive should be replaced

as soon as possible

following the guidelines in

the “Recovering from Hard

Drive Failure” (Appendix E)

in this guide.

86 DRIVE
POSITION CHANGE
DETECTED

Informational

The SCSI drives that make

up a configured volume

have been physically

moved within the

MSA1000 or an attached

storage enclosure. The

array controller has

updated its configuration

information accordingly.

87 DRIVE
POSITION CHANGE
INVALID

Informational

The SCSI drives that make

up a configured volume

have been physically

moved in such a way that

the array controller can no

longer access the

configured volume.

The MSA1000 should be

powered off and the drives

restored to their original

positions.

Table 3: LCD Message Descriptions

Message

Type

Description

Action