Controller Display Messages
60
515 FIBRE DEVICE
HARDWARE FAILURE
Error
The fibre device that is
installed in the MSA1000
fibre bay was not
recognized by the array
controller.
Verify the fibre device is
supported by the
MSA1000 by checking the
documentation that came
with it. If it is supported
then remove the fibre
device, wait one minute
and then reinsert it insuring
it is fully seated in the
chassis. Wait one minute
and check the LCD to see if
a new copy of this error
message is created. The
service indicator LED on
the back of the switch
should turn solid green if
the device is operating
normally. The service
indicator LED will flash
amber if it has failed
again.
Should the issue persist,
please contact HP support.
516 FIBRE
SUSBYSTEM LINK
FAILURE
Error
There is no active fibre
connection to this
MSA1000 array controller
(Laser OFF).
If the Fibre connection is a
direct-connect from an
HBA to the MSA1000, this
message is expected when
the server is powered off or
restarted.
Power on the server and
load the HBA drivers.
If the status does not
change to OK, check
cables, fibre bay board,
SFP, and HBA.
517 FIBRE
SUBSYSTEM LINK
OK
Informational
There is an active fibre
connection to this
MSA1000 array controller
(Laser On).
This message is only
displayed when preceded
by message 516.
Table 3: LCD Message Descriptions
Message
Type
Description
Action