beautypg.com

HP StorageWorks 1000 Modular Smart Array User Manual

Page 59

background image

Controller Display Messages

59

MSA1000 Controller User Guide

510 INITIALIZING
FIBRE SUBSYSTEM

Informational

The array controller’s fibre

subsystem is being

initialized as part of the

power up sequence.

513 UNCORRECTED
ECC MEMORY ERROR
SEEN

Error

The array controller has

detected an uncorrectable

error in the ECC memory

on the memory cache

board.

Remove the failed array

controller and replace the

memory cache board with

a new one.

514 FIBRE SWITCH
HARDWARE FAILURE

Error

The MSA SAN Switch 2/8

that is installed in the

MSA1000 failed to

establish a connection with

the array controller over

fibre channel.

Remove the MSA Fabric

Switch 6 switch, wait one

minute and then reinsert it

insuring it is fully seated in

the chassis. Wait one

minute and check the LCD

to see if a new copy of this

error message is created.

The service indicator LED

on the back of the switch

should turn solid green if

the switch is operating

normally. The service

indicator LED will flash

amber if it has failed

again.

Should the issue persist

please contact HP support.

Table 3: LCD Message Descriptions

Message

Type

Description

Action