HP StorageWorks 1000 Modular Smart Array User Manual
Page 51

Controller Display Messages
51
125 ACCESS
CONTROL CONFLICT
DETECTED
Error
A set of volumes have been
migrated from one array
controller to a different
array controller that
already has configured
volumes on it. The migrated
volumes have access
controls defined for them
that conflicts with the
existing configuration. The
access controls has been
modified so as to allow the
migration to proceed.
Run the Array
Configuration Utility (ACU)
to check the new access
controls and modify them if
needed.
126 ACCESS
CONTROL
RESOURCES
EXCEEDED
Error
A set of volumes have been
migrated from one array
controller to a different
array controllers that
already has configured
volumes on it. The migrated
volumes have access
controls defined for them
that conflicts with the
existing configuration. The
access controls has been
modified so as to allow the
migration to proceed.
Run the Array
Configuration Utility (ACU)
to check the new access
controls and modify them if
needed.
201 ARRAY
CONTROLLER
TEMPERATURE OK
Informational
The temperature sensor on
the array controller
indicates that the
temperature which was
previously exceeding the
normal operating range is
now back within the range.
Table 3: LCD Message Descriptions
Message
Type
Description
Action