Controller Display Messages

44

MSA1000 Controller User Guide

72 CACHE ERROR
IGNORE? <=NO
>=YES

User Input

During power up, data was

found in the cache that

could not be flushed to the

drives. The reason is either

because the data does not

belong to this array

controller (the cache board

was moved from a different

array controller) or the

cache data is partial (the

rest of the data is in

another cache board that

was removed from the

array controller). This error

could occur if cache

boards are moved

improperly.

The

no

option will cause

the array controller to halt

itself, providing the user an

opportunity to resolve the

issue. Selecting the

yes

option will result in the

cache data being erased.

Operation of the array

controller will continue

normally.

Error

1.1

and

1.2

: There is

only one cache board in

the array controller at

present but it was

previously configured with

a second cache board that

is now missing (dual cache

module configuration).

Error

2.1

and

2.2

: A

second cache board that

contained valid data was

removed from its original

array controller and added

to this array controller

(dual cache module

configuration). Error

2.3

: A

cache board that

contained valid data was

removed from its original

array controller and added

to this array controller

(single cache module

configuration). Return all

cache boards to their

original array controllers.

Power up the systems

without allowing any host

I/O and wait for the cache

data to be written to the

drives. This will take a few

minutes after the systems

have finished the power on

sequence. The systems can

be powered off and cache

boards moved to their new

locations.

Table 3: LCD Message Descriptions

Message

Type

Description

Action