Lcd message descriptions – HP StorageWorks 1000 Modular Smart Array User Manual
Page 32
Controller Display Messages
32
LCD Message Descriptions
The following table contains the defined messages and their components.
Table 3: LCD Message Descriptions
Message
Type
Description
Action
00 ARRAY
CONTROLLER
FIRMWARE VER
Informational
Displays the current version
of the firmware running on
the array controller.
01 MSA1000
STARTUP COMPLETE
Informational
The array controller has
completed its power on
sequence and is now
operational.
02 ENABLE VOLUME
‘>’=YES
User Input
An issue has been found
with a configured volume
that may result in data loss.
The exact nature of the
issue will be detailed in a
previous display message.
Selecting the
no
option will
result in the volume being
disabled so the user can
attempt to fix the issue.
Selecting the
yes
option
will result in the volume
being enabled regardless
of the issue.
03 CRITICAL
LOCK-UP
DETECTED.
CODE=
Error
A critical error has been
detected by the array
controller firmware. In
order to prevent any
possible data loss, the
firmware has entered a
lock-up state. The code
contains engineering
specific information about
the lock-up condition. HP
support should be
contacted.
Remove the failing array
controller, wait 10 seconds,
and then reinsert it insuring
that it is fully seated in the
chassis.
Should the issue persist
please contact HP support.
04 ENABLE
VOLUMES ?
‘<’=NO, ‘>’=YES
User Input
An issue has been found
with all of the configured
volumes that may result in
data loss. The exact nature
of the issue will be detailed
in a previous display
message.
An issue has been found
with all of the configured
volumes that may result in
data loss. The exact nature
of the issue will be detailed
in a previous display
message.