Replacing the controller cache battery pack – HP StorageWorks 1000 Modular Smart Array User Manual
Page 18

MSA1000 Controller
18
Replacing the Controller Cache Battery Pack
WARNING:
There is a risk of explosion, fire, or personal injury if the battery
pack is replaced incorrectly or mistreated. To reduce the risk:
■
Do not attempt to recharge the battery outside of the controller.
■
Do not expose to water, or to temperatures higher than 60°C.
■
Do not abuse, disassemble, crush, puncture, short external contacts, or
dispose of in fire or water.
■
Replace only with the spare designated for this product.
■
Array Accelerator battery disposal should comply with local regulations.
Alternatively, return them by established parts return methods to
Hewlett- Packard Corporation for disposal.
Caution:
It is important to follow these instructions when replacing
components in the MSA1000. If the procedure is done improperly, it is
possible to lose data or damage equipment. Refer to the “
” appendix for important information on using the proper
procedures.
To remove the old NiMH battery pack:
1. Remove the MSA1000 Controller Cache, as instructed in the previous
section, “
Replacing the MSA1000 Controller Cache
2. Push down on the bottom clip of the battery pack, attached near the lower
corner of the Array Accelerator.
See