110 VOLUME #
EXPANSION
DISABLED
Informational
The volume expansion
operation on the
configured volume has
been disabled. This may be
because a rebuild
operation is ongoing,
another expansion is
already running, or the
cache memory is disabled
due to a low battery. The
expansion will start once
the condition has been
cleared.
111 VOLUME #
INITIALIZING
PARITY
Informational
The array controller is
calculating and storing
parity information for the
configured volume and
therefore performance may
be lower until it completes.
112 VOLUME #
REBUILD FAILURE
Error
The rebuild operation on
the configured volume has
failed.
If the volume is still
operating in regenerative
mode, remove the new
SCSI drive that was added
as a replacement for the
original failed drive and
replace it with a different
new drive.
113 VOLUME #
EXPANSION
FAILURE
Error
The volume expansion
operation on the
configured volume has
failed.
Run the Array
Configuration Utility (ACU)
and use it to determine the
state of the volume. If the
volume is still operational
then it is possible to
reattempt the operation.
114 VOLUME #
STATE DELETED
Informational
The configured volume has
been deleted and is no
longer available. Volumes
are deleted by using the
Array Configuration Utility
(ACU).
120 CONFIGURED
VOLUMES
Informational
The specified number of
configured volumes were
detected at power up.
Table 3: LCD Message Descriptions
Message
Type
Description
Action