Controller Display Messages

49

MSA1000 Controller User Guide

110 VOLUME #
EXPANSION
DISABLED

Informational

The volume expansion

operation on the

configured volume has

been disabled. This may be

because a rebuild

operation is ongoing,

another expansion is

already running, or the

cache memory is disabled

due to a low battery. The

expansion will start once

the condition has been

cleared.

111 VOLUME #
INITIALIZING
PARITY

Informational

The array controller is

calculating and storing

parity information for the

configured volume and

therefore performance may

be lower until it completes.

112 VOLUME #
REBUILD FAILURE

Error

The rebuild operation on

the configured volume has

failed.

If the volume is still

operating in regenerative

mode, remove the new

SCSI drive that was added

as a replacement for the

original failed drive and

replace it with a different

new drive.

113 VOLUME #
EXPANSION
FAILURE

Error

The volume expansion

operation on the

configured volume has

failed.

Run the Array

Configuration Utility (ACU)

and use it to determine the

state of the volume. If the

volume is still operational

then it is possible to

reattempt the operation.

114 VOLUME #
STATE DELETED

Informational

The configured volume has

been deleted and is no

longer available. Volumes

are deleted by using the

Array Configuration Utility

(ACU).

120 CONFIGURED
VOLUMES

Informational

The specified number of

configured volumes were

detected at power up.

Table 3: LCD Message Descriptions

Message

Type

Description

Action